BCI Capnocheck II Capnograph/Oximeter w/battery & charger
* Measures ETC02, Inspired C02, Respiration Rate, Sp02 and Heart Rate
* Provides waveforms, numeric values and on-screen trending
* Easy-to-read EL back-lit LCD display
* Adjustable alarm limits, as well as visual and auditory alarms
* Sidestream technology accommodates intubated and non-intubated patients
* Lightweight for easy transport
* Infrared link to an external printer assures trouble-free download
* Monitor patients ranging from pediatric to adult
The Capnocheck II Hand-Held CO2/SpO2 Monitor provides measurements of End Tidal CO2, respiration rate, SpO2 and pulse rate with N2O compensation, for patients pediatric to adult. The monitor utilizes a LCD backlit display with on-screen trending and high and low alarm limits for all parameters. A protective rubber boot is also included, and the infrared serial interface allows downloading patient information to a printer. This highly portable hand-held monitor is ideal for EMS, Emergency Rooms, Recovery Rooms, and intra-hospital transport.
Includes: 8400 Monitor, 1894 Operation Manual, 3044 Oximetry Finger Sensor (model 8400), 8412 Protective Rubber Boot, 8214 Patient Attachment Kit includes the following: 8208 Capnocheck Filters (10), 8211 Capnocheck Sample Lines, 4 ft (10), 1100 Airway Adapter, straight without filter (10).
* Display: LCD, with EL back light
* Calibration: Manual 2 point
* Measurement: 0 to 10% CO2 STPD (standard temperature and pressure dry)
* Display Range : 0 to 100 mmHg; 0-13 kPa; 0-10% C02
* Accuracy: +/-2mmHg or 4% of reading, whichever is greater
* System Response Time: 2.46s to 90% with 8 ft. patient line Response Time
* N20 Compensation selectable 40% (default = OFF)
* Averaging 4-breath average
* Flow Rate 120+/-20 ml/min
* Range: 0 to 150 breaths/min
* Range: 0 to 100% SP02 (functional)
* Accuracy: +/-2% at 70 to 100% Sp02, less than 70% unspecified
* Accuracy: +/-2 bpm or 2%, whichever is greater
* Infrared Port compatible with HP82240B Printer or similar device.
* Data Format: Non-standard format - 500 baud
* AC Power: 120V-, 60Hz; 230V-, 50/60Hz
* Battery: Lithium-Ion, 7.4 VDC Replaceable, internal rechargeable. Fully-charged continuous life of approximately 6 hours. Maximum full-capacity charging is 2.5 hours.
* Dimensions: 5.0"H x 4.38"W x 2.9"D (122mmx111mmx73.7mm)