1, the detection limit: 0.05ng/ml b (5 10-11g/ml).
2, the measured uranium range :0-20ng / ml for the higher concentrations of the samples requires appropriate dilution.
3, Accuracy: less than 5% (1 ng / ml measurements).
4, linear correlation coefficient: r 0.998.
5 Stability: 1 ng / ml two hours of determination of the stability of the sample is not more than 10%.
6, sample volume: 5ml sample +0.5 ml J-22 reagents (each measurement).
7, excitation source: a small sealed nitrogen molecular laser.
Instrument working conditions:
1, power supply voltage of 220V 5%, 50Hz 0.5Hz, a larger region in the voltage need to use the exchange regulators.
2, the working temperature should be 10 - 35 , this is because the J-22 reagents in less than 0 when the crystal.
3, on the Preparation of blank and standard samples used in secondary distilled water or deionized water, the amount of uranium-containing checks, blank values should not exceed 0.01-0.02 ng / ml uranium.
WGJ- laser uranium analyzer uses laser fluorescence method to measure liquid samples of trace uranium, uranium in the liquid with uranyl ion (uO2) 2 + exists, with the addition of a special J-22 uranium fluorescence enhancer, uranyl ion envelope so that efficient synthesis of a single fluorescent complexes. The complex molecules by a small sealed nitrogen laser shot irradiation of UV laser pulses, resulting in 5000,5220,5460 A0 fluorescence wavelength. This characterization of the fluorescence intensity of the uranium content of samples.
- We answer ALL questions, if you do not get a response within a reasonable amount of time, please remember it may be the weekend, or we did not get your email. Many times spam filters, or various other email problems can cause them to get lost, messages coming to us or going back to you.
We also have these products, hoped that you may use
1 SDM2000 individual dose Alarm
3 FJ2000 individual dose Alarm
4 FJ3200 individual dose Alarm
4 LH-I of individual dose Alarm
5 FY-II radiation acoustic instrument
6 AFY-I can be inhaled radioactive dust sampler
7 REM-III Radon Exhalation Rate Instrument
9 DHZM-II measuring radon and daughter
10 RLM-I continuous radon monitor
11 ASM-I of soil radon measuring instrument
12 RDS-08 Portable X- dose-rate instrument
13 RAM-I fixed x- -line Radiation Alarm
15 D50 low-end of a measuring instrument in this
16 RAM-SURF- 1 a surface contamination meter
17 RPCM-1 surface contamination Instrument
18 large, medium and small lead in radiation protection clothing
19 WRM-I in the water radioactive Alarm (online monitoring)
20 CXF-2 (F) of respirable dust personal sampler
21 SSM-1 multi-functional radiation protection survey meter
22 ERM-C environmental radiation meter
23 LM-1 portable radioactive aerosol measuring instrument
25 LUM-1 Trace Uranium Analyzer (formerly the laser uranium analyzer)
27 RAM-3 radiation survey meter
28 D-30 radioactivity measuring instrument



Analyzer trace uranium