Kenosha Reuse Discussion Board   >   SALEM, WI   >   Commercial   >   Industrial   >   System sensor fire alarm control panel sprinkler

System sensor fire alarm control panel sprinkler


Up for sale is a PDRP - 2001 Fire Alarm Control Panel. The PDRP-2001 panel supervise wiring, AC voltage, battery charge, and
battery level. It has four outputs that are programmable as notification appliance circuits
(NACs) or releasing circuits. Three programmable Form-C relays (factory programmed for
alarm, trouble and supervisory) and 24 VDC special application resettable and non-resettable
power outputs are also included on the main circuit board. It is a little dusty but is in perfect working order. See below for specs.
The PDRP-2001 and PDRP-2001E fire alarm control panels (FACPs) are compatible with the System Sensor i3 Series conventional smoke detectors that transmit signals to the FACP to indicate important status conditions such as low temperature 45 F (7.22 C) or required maintenance. This control panel is compatible with conventional input devices such as waterflow devices, tamper switches, 2-wire smoke detectors, 4-wire smoke detectors, pull stations, and other normally-open contact devices. The PDRP-2001 and PDRP-2001E panels supervise wiring, AC voltage, battery charge, and battery level.
An installed waterflow detector or compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.
Four outputs are programmable as notification appliance circuits (NACs) or releasing circuits. Three programmable Form C relays (factory programmed for alarm, trouble, and supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board.
Unless otherwise specified, the information in this data sheet applies to both the 110/120 VAC and 220/240 VAC versions of the panels.
* Designed for sprinkler standards NFPA 13, 15, and 16
* Allows connection to 220/240 VAC
* Adjustable water flow discharge timer and two soak timers
* Cross-zone (double-interlock) capability
* 6 programmable Style B (Class B) IDCs (Initiating Device Circuit)
* System Sensor i3 Series detector compatibility
* 4 programmable Style Y (Class B) output circuits (special application power)