Includes: New Fujikura 60S fusion splicer with yellow case, btr-08 battery, ct-30a cleaver, adc013 ac adapter, dcc-14 battery charging cord, acc-14 ac power cord, spare pair of new electrodes, sheath clamp, USB cable, carrying strap and .pdf instruction manual. SurplusEQ.com is not an AFL Distributor. AFL will not service this splicer. For service and repairs, contact SurplusEQ.com. May be subject to stock on hand. Contact us for availability
The Fujikura FSM-60S fusion splicer sets the standard for core alignment fusion splicing by incorporating a user-friendly interface with enhanced features to provide the most rugged and reliable fusion splicer in the market today. The new rugged construction adds improved reliability by resisting shock, dust, and rain, and can withstand a 30 drop test.
The FSM-60S splices a fiber in 9 seconds and heats a 60mm splice sleeve in 30 seconds, for a total cycle time of only 39 seconds. New features, such as automatic tube heater operation, user-selectable clamping method (sheath clamp or fiber holder system), automated monitor image orientation, and battery charge capability during splicer operation provide the end user a productivity tool they can
Cladding Diameter: 80 to 150 m.
Coating diameter: 100 to 1000 m
Fiber setting and cleaved length
Sheathe clamp A (standard): For coating dia. up to 250 m (8 to 16mm cleave), coating dia. of over 250 m (16 m cleave)
Sheathe clamp B (option): For coating dia. up to 1000 m (8 to 16mm cleave)
Sheathe clamp C (option): For 900 m dia. loose tube fiber (8 to 16mm cleave)
Fiber holder (option): FH-60-250 and FH-60-900 (10mm cleave)
(Measured by cut-back method relevant to ITU-T standard)
13 sec. with AUTO modes with standard SM (ITU-T G.652)
Real-time and by using results of previous splice when in AUTO mode
Manual arc calibration function available
Intentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an in-line fixed attenuator.
Built-in tube heater with 30 heating modes / Typical 30 sec. with Fujikura FP-03
60mm 40mm and Fujikura FPS01 series
the last 2000 results to be stored in the internal memory
0 to 5,000m above seal level, 0 to 95%RH and -10 to 50 C and up to 15m/s wind velocity, respectively
0 to 95%RH and -40 to 80 C respectively. Battery: -20 to 30 for long term
136Wx161Dx143H (mm) excluding rubber foot
Two CMOS cameras and 4.1" color LCD monitor
X/Y (300X magnification), or both X and Y simultaneously (187X magnification)
Applicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13. 13.2V DC with BTR-08
No. of splice cycles with battery
Typical 160 cycles (splice / tube heat) with BTR-08
USB 1.1 (Mini-B type) connector for PC communication.
6-pin Mini-DIN connector for HJS-02, HJS-03 or SH-8C power supply