Kenosha Reuse Discussion Board   >   KENOSHA, WI   >   Commercial   >   Mechanical   >   New   >   Amersham 80-6406-80 DQ200 dynaquant flourometer

Amersham 80-6406-80 DQ200 dynaquant flourometer


This listing is for a fluorometer.
* Make: Amersham (Part of GE Life Sciences)
* Model / Part # 1: 80-6406-80 (806406-80) (80-640680) (80640680)
* Model / Part # 2: DQ-200 (DQ200)
* Input Power: Standard 115V/230V: 47-63Hz: 15W: Fuses N/A
* Description: Fluorometer
* Power Requirements: 90-260VAC, 47-63Hz, 15W (115V and 230V)
* Light Source: Mercury lamp (expected life 5,000 hours)
* Excitation Range: 365nm + 7nm @ FWHM
* Emission Range: 460nm + 15nm @ FWHM
* Detector: Silicon photodiode
* Sensitivity: 10ng/ml in standard 1 cm path cuvettes (Hoechst DNA assay)
* Dimensions(hwd): 12 X 16 X 35 cm
Accurate Quantitation of your DNA Sample from 10ng/ml to 5ug/ml
* Accurate, precise detection of DNA even in the presence of RNA, proteins and/or nucleotides
* Measures enzyme activity based on methylumbelliferyl and other similar fluorescent substrates
* 200-300 times more sensitive than UV/Visible spectroscopy
Quantitate DNA from 10 ng/ml to 5 g/ml in a Standard Cuvette
The DyNA Quant 200 fluorometer is designed specifically for the accurate quantitation of small volume samples with low DNA concentrations using the Hoechst 33258 dye. The dye binds preferentially to double-stranded DNA, thus allowing accurate quantitation even in the presence of RNA, proteins and/or nucleotides and in cell lysates.
Improve Realiability of Analytical and Preparative Steps
If you know the exact DNA concentration of your sample, the results of your subsequent PCRTM, RFLP, subcloning or sequencing reactions will be more reliable and easier to compare to previous experiments.
The DyNA Quant 200 fluorometer can also measure enzyme activity based on the cleavage of methylumbelliferyl-linked substrates and other fluorescent substrates with similar excitation and emission characteristics (365 nm ex, 460 nm em). Enzymes that can be assayed with fluorescent substrates include -galactosidase (gus), and proteases.
Amersham manual is located at http://www1.gelifesciences.com/aptrix/upp00919.nsf/Content/16EB3E1EB9ECE627C1257628001CD6FB/$file/80623086.pdf



Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer Amersham 80-6406-80 DQ200 dynaquant flourometer