Kenosha Reuse Discussion Board > GURNEE, IL
> Commercial
> Automative
> Used
> Pyrolaser high temperature infrared thermometer
Pyrolaser high temperature infrared thermometer
Pyrolaser High Temperature Infrared Thermometer
The Pyrometer portable Pyrolaser infrared thermometer uses the latest pulsed laser technology to precisely measure the true target non contact temperature measurement. While all non contact infrared thermometer instruments measure a target radiance temperature, the Pyrolaser dynamically determines a targets emissivity value resulting in unmatched temperature accuracy to 3 C. With Pyrolaser , laboratory precision temperature measurements can be obtained in a portable easy to use instrument.
The Pyrolaser incorporates an electronic microprocessor control unit, LCD digital display, membrane keypad, power supply, and temperature measurement output connections and precision glass optics. The Pyrolaser can be operated from the instrument's keypad or remotely from a PC. The Pyrolaser's microprocessor control measures radiance, emissivity, and background radiance values at an extremely fast 1ms data acquisition rate.
The Pyrolaser automatic emissivity correcting IR thermometer is used for many industrial and laboratory applications. This includes temperature measurement in refractories, ovens, furnaces and vacuum chambers. Virtually anywhere accurate portable IR temperature measurements are required.
* Petroleum Furnace Tube Temperatures
* Refractory Temperature Measurement
* Production Steel Annealing Furnaces
* Production Copper Furnaces
* Ceramic & Graphite Production
* Forgings & Quality Control Applications
The Pyrolaser infrared thermometer reads the radiance emitted from a hot target. The Pyrolaser then fires its pulse laser at the target. The reflected energy from the laser is then collected by the Pyrolaser . Extraneous background radiance from other sources (Tx) "wall shine readings"can be collected should the application require. The Pyrolaser's microprocessor control processes all the data collected (radiance, laser return & wall shine) and displays the results on the Pyrolaser's LCD display. Displayed data includes uncorrected temperature (Tu), emissivity value (E) and emissivity corrected temperature measurement (Tt), accurate to 3 C.
Optional Extended Temperature Ranges:
See Calibration Lens & Filter Table Below)
Automatic Emissivity Measuring Range:
4 Digit Corrected Temperature (Tt)
40 Digit Readout of Target Distance Emissivity Value (E), Uncorrected Temperature (Tu), & Corrected Temperature (Tt)
Optional Target Distances Available
See Calibration Lens & Filter Table Below
Optional Target Size/Distances Available
(Target Size = 1/200 of Target Distance)
0.333 (1mm @ 20cm; 0.04" @ 8")
1, 2, 4, 8, 21, 23, 37 Readings/sec Selectable
Maximum Equipment Operating Temperatures:
Target Uncorrected Temperature
Target Emissivity Corrected Temperature
Single Analog Output: 0 -5vdc or 0-20mA
Single Digital Output : RS232C
(3) x 9v Rechargeable Ni Cad Batteries
115v/60Hz or 230v/50Hz Charger
2 Hours Operating Time w/Batteries - Unlimited Operating Time With Charger.
12.5" x 8.0" x 3.0" (318mm x 211mm x 74mm)
Optional Snap-On Lenses For Additional Target Size and Distances
Select Up To Four Ranges / Lenses
Temperature Range: 600 C - 1500 C
Temperature Range: 700 C - 2000 C
Temperature Range: 790 C - 2500 C
Temperature Range: 850 C - 3000 C
The Unit in Perfect working order come with ,PL 103 8.m lens ,battery charger new battery ,User manual and original carring case.