The development of the AMI Model 2010BR trace oxygen analyzer began with a collection of inputs from hundreds of industry leading engineers and field technicians in the natural gas and petrochemical industries.
patented cell block technology. The front panel user interface is very intuitive for ease of operation and for the advanced users we provide an RS-232 connection to access the more advanced
Cutting Edge Microprocessor Based Electronics
High-resolution single range 3 Digit LCD
10 user-selectable output ranges: 0-10ppm, 0-50ppm,
0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%,
0-10% and an air calibration range of 0-25%
The user selection of an output range simultaneously
controls both alarm functions, the analog output and the
data logger so that all 4 functions operate on the same
2 independent, fully adjustable alarm settings with
User selectable alarm logic: latching or non-latching,
Open on Alarm or Close on Alarm
Programmable alarm delays: Settings range from
0-300min. This feature prevents alarm conditions due to
quick H2S spikes or short-term operator error.
Alarm bypass button: Prevents false alarms while
performing monthly calibrations.
User settable from 0-120 minutes
Data logger: Logs data for 15 days @ 1min intervals and
30 days @ 2min. intervals, etc.
Cal Factor: indicates remaining O2 sensor life
User selectable security settings
Isolated 1-5VDC and 4-20mA. analog outputs
Simple intuitive front panel user interface
Available in either AC or DC power.
Available with or without explosion proof heater
AMI's patented cellblock begins with a single compact metallic block that undergoes a complex machining process, followed with corrosion-resistant nickel plating. The block contains a series of drilled intersecting gas passages and mounted directly on it are: a custom designed flow control valve, 3-way selector valve (for sample/span/shut off control), flow meter and 3 gas connection fittings. All become an integral part of the cellblock. This eliminates the techniques used by competitors of piecing several lengths of tubing between numerous compression fittings, valving and a flow meter. In using this approach, they add many potential leak paths, increase response times, the need for additional space and additional employee labor. Lastly, our front panel sensor access makes the O2 sensor installation or replacement quick and easy without tools or the
need to remove any sensitive components. It also allows for a rapid, accurate calibration on ambient air (20.9%) without the use of tools. A span gas port comes standard for those who prefer a certified span gas calibration. The accurate air calibration takes less than 1 minute from start to finish! Our advanced design approach has separated us from the competition with the highest performance, yet lowest cost
oxygen analyzer in the industry. When the application requires, we can provide one of our
patent pending H2S resistant oxygen sensors (up to 500ppm H2S exposure for its warranted life) to meet your needs. This breakthrough sensor technology eliminates the need for maintenance intensive H2S scrubbers.